Reactors

Input & Output Reactors

Series / Model · ACL / OCL

Product overview

The input and output reactor family combines ACL input reactors and OCL output reactors for the respective mains and motor sides of variable-frequency drives. Selection data, voltage drop and application position are confirmed separately for each subseries.

CORE FEATURES

Core features

ACL and OCL are presented as distinct subseries within one product family
Input-side and output-side applications, voltage drop and models are selected separately
Class H composite insulation and vacuum impregnation
Power, current, inductance and dimensions are confirmed against the official model tables

SUBSERIES TECHNICAL DATA

Subseries technical data

Technical data is taken from the Shanghai GBL Reactor Product Catalogue. ACL and OCL models and parameters must be confirmed against their respective tables.

ACL Input Reactor

Installed between the mains supply and a variable-frequency drive to suppress input harmonics and current surges and improve power factor.

Operating voltageAC 380 / 690 / 1140 V
Rated-current range5–1600 A
Voltage-drop tables380 V: 2% / 4%; 690 V: 2%
Model / ordering basisSelect from the catalogue model table by rated power, rated current, voltage drop and inductance
Dimensions & mountingOverall and mounting dimensions vary by rated power and current; use the exact model table
Dielectric test & insulation resistanceCore-to-winding: 3000 VAC / 50 Hz / 5 mA for 60 s; insulation resistance ≥100 MΩ at 1000 VDC
Temperature-rise limitsCore <85 K; winding <95 K
Overload capability1.2 × rated current
Linearity / phase balanceLinearity ≥0.95 at 1.8 × rated current; reactance balance ≤±2%
Insulation class / noiseClass H; noise <65 dB at 1 m
Operating environmentAltitude ≤1500 m; -25°C to +45°C; relative humidity ≤90%
StandardsGB 1094.6 / GB 19212.1 / GB 19212.21

OCL Output Reactor

Installed between a variable-frequency drive and motor to reduce output dv/dt and mitigate long-cable distributed capacitance.

Catalogue voltage coverageAC 380 / 690 V model tables
Voltage-drop tables380 V: 1% / 2%; 690 V: 1%
General rated-current range5–1600 A (general inverter-reactor technical conditions)
Model / ordering basisSelect from the catalogue model table by rated power, rated current, voltage drop, inductance and transmission conditions
Dimensions & mountingConfirm overall and mounting dimensions against the exact power, current and model table
Dielectric test & insulation resistanceCore-to-winding: 3000 VAC / 50 Hz / 5 mA for 60 s; insulation resistance ≥100 MΩ at 1000 VDC
Temperature-rise limitsCore <85 K; winding <95 K
Overload capability1.2 × rated current
Linearity / phase balanceLinearity ≥0.95 at 1.8 × rated current; reactance balance ≤±2%
Insulation class / noiseClass H; noise <65 dB at 1 m
Operating environmentAltitude ≤1500 m; -25°C to +45°C; relative humidity ≤90%
StandardsGB 1094.6 / GB 19212.1 / GB 19212.21

AVAILABLE SERIES

Available models / series

ACL Input ReactorOCL Output Reactor

APPLICATIONS

Applications

01

Harmonic and surge-current suppression at variable-frequency drive inputs

02

Output-circuit coordination between variable-frequency drives and motors

03

Industrial motor speed-control and long-cable drive systems

TECHNICAL DOCUMENTS

Technical Documents

Manuals, technical drawings, BIM files and other resources are published once approved.

01

ACL / OCL / CKSG Reactors

Shanghai GBL Reactor Product Catalogue

Model
ACL / OCL / CKSG
PDF · Official Product Catalogue · 36.4 MB